![]() |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
News & Events | Press ReleasesSionex Introduces the microAnalyzer, Trace Chemical Detector System New product will speed integration of Sionex technology into OEM systems for threat detection, process control, monitoring, and medical diagnostics BEDFORD, Mass., October 15, 2008 - Sionex Corporation, a leading producer of chemical sensors and sub-systems, today announced the introduction of the microAnalyzer™, an integrated system that can quickly detect, identify and measure extremely minute quantities of chemicals in air or vaporized liquids at the point of collection. The microAnalyzer is the first product to provide, in one, small, portable package, an (oven-less) gas chromatographic (GC) separation module and Sionex's patented microDMx™ sensor, dramatically improving selectivity in complex chemical environments. Sensitivity is typically in the range of parts per trillion, while the speed of the microDMx technology allows for processing times between 30 seconds and five minutes. Building on Sionex's years of experience working with OEMs to integrate its technology into their products, the compact microAnalyzer is designed to be rapidly incorporated into systems. The microAnalyzer's modular design makes possible the use of different traps and GC columns to tailor it for a specific application. "Our experience with OEMs in markets as diverse as threat detection, process control, monitoring, and medical diagnostics has enabled us to create a product that provides the unique functionality that our OEM customers demand, combined with the flexibility they need to create products that meet their customers needs," said Wes Davis, president and CEO of Sionex. "The microAnalyzer allows OEMs to speed their development process, bringing their advanced systems to market more quickly and cost-effectively. "Sionex's microDMx – based on Differential Mobility Spectroscopy – is a very small, fast, accurate chemical sensor that will have broad application in a wide range of industries. With the microAnalyzer, we are targeting those industries that are moving most aggressively – right now – to adopt advanced technology for trace chemical detection." The microAnalyzer uses a combination of a GC separation module and Sionex's proprietary technology to analyze a gas phase or vaporized liquid to detect, identify and measure the chemicals in it to the level of parts per trillion. The microAnalyzer produces near-real-time data that can trigger alerts, monitor conditions, generate diagnostic reports, or manage manufacturing processes. The product features a touchscreen display that shows target compounds, concentrations and alarm notification. A separate alarm level can be set for each target compound. Detection algorithms are easily downloaded for instrument operation and control. The entire unit is merely 9.5 in. long by 5.25 in. wide by 3.5 in. high. The microAnalyzer is primarily aimed at OEMs who make products for the threat detection/defense, process control, monitoring and medical devices markets. Taking advantage of the microAnalyzer’s unique capabilities, size and cost, they incorporate it into complete solutions for their established customer bases. These systems range from chemical warfare agent detectors for the battlefield to process manufacturing management systems, from environmental monitoring equipment to medical diagnostic devices analyzing human breath. The price of the microAnalyzer varies depending on order size, from, for example, $11,000 a unit in volumes of 100 to 199 to $7,500 a unit in volumes of 1,000 or more. It is available for shipping 30 days after receipt of order. ABOUT SIONEX CORPORATION Sionex Corporation provides breakthrough chemical and biological sensor chips and subsystems based on its proprietary microDMx detection technology. Sionex maintains its worldwide headquarters and laboratories in Bedford, Massachusetts. The Company is privately held and was founded in 2001 with patented technology exclusively licensed from the Charles Stark Draper Laboratory. Additional information about Sionex Corporation is available at www.sionex.com. Safe Harbor Statement Forward-looking Statement This press release contains forward-looking statements that involve risks and uncertainties concerning Nano-Proprietary's business, products, and financial results. Actual results may differ materially from the results predicted. More information about potential risk factors that could affect our business, products, and financial results are included in Nano-Proprietary's annual report on Form 10-K/A for the fiscal year ended December 31, 2006, and in reports subsequently filed by Nano-Proprietary with the Securities and Exchange Commission ("SEC"). All documents are available through the SEC's Electronic Data Gathering Analysis and Retrieval System (EDGAR) at www.sec.gov or from Nano-Proprietary's website listed above. Nano-Proprietary hereby disclaims any obligation to publicly update the information provided above, including forward-looking statements, to reflect subsequent events or circumstances. # # # microAnalyzer™ and microDMx™ are trademarks of Sionex Corporation. EDITORIAL CONTACTS: Eric Kirleis microDMx™ and Protection by Detection™ are trademarks of Sionex Corporation. |
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| © 2006 SIONEX Corporation |
||