Protection by Detection  
   

Selected Technical Papers

Field dependence of mobility for gas phase protonated monomers and proton bound dimmers of ketones by a planar field asymmetric waveform ion mobility spectrometer. Krylov E., Nazarov E.G., Miller R.A., Tadjikov B., Eiceman G.A.  J. of Physical Chemistry A, June 2002

Micro-machined planar asymmetric ion mobility spectrometer as a gas chromatographic detector. Eiceman G.A., Nazarov E.G., Miller R.A., Krylov E., Zapata A.  The Analyst, 2002, 127

Application of mobility theory to the interpretation of data generated by linear and RF excited ion mobility spectrometers. Spangler G.E., Miller R.A.   Int. J. Mass Spectrometry 2002, v214, 95-104

Miniature radio-frequency mobility analyzer as a gas chromatographic detector for oxygen-containing volatile organic compounds, pheromones and other insect attractants. Eiceman G.A., Tadjikov B., Krylov E., Nazarov E.G., Miller R.A., Westbrook J., Funk P. J. Chromatographic A, 2001 v917, 205-217

A MEMS radio-frequency ion mobility spectrometer for chemical vapor detection. Miller R.A., Nazarov E.G., Eiceman G.A., King A.T.  Sensors & Actuators A, 2001, v91, 307-318

A MEMS radio-frequency ion mobility spectrometer for chemical agent detection. Miller R.A., Nazarov E.G., Eiceman G.A., King A.T.  Solid state Sensor & Actuator Workshop, Hilton Head Island, 2000, 120-123

Monitoring volatile organic compounds in ambient air inside and outside buildings with the use of a radio-frequency based ion mobility analyzer with a micromachined drift tube. Eiceman G.A., Nazarov E.G., Tadjikov B., Miller R.A.  Field Analytical Chemistry & Technology, 2000, v4, 297-308

A micromachined ion mobility spectrometer / mass spectrometer. Eiceman G.A., Nazarov E.G., Miller R.A.   Int. J for Ion Mobility Spectrometry, 2000, v3, 15-17

A novel micromachined high-field asymmetric waveform - ion mobility spectrometer. Miller R.A., Eiceman G.A., Nazarov E.G., King A.T. Sensors & Actuators B, 2000, v67, 300-306

Surface ionization gas-analyzing devices with separation of ions by mobility. Rasulev K, Nazarov E.G., Palitsin V.V.   Proceedings of the 4th International Workshop on Ion Mobility, Cambridge UK, 1995, 15

A new method of separation of multi-atomic ions by mobility at atmospheric pressure using a high-frequency amplitude asymmetric strong electric field. Buryakov I.A., Krylov E.V., Nazarov E.G., Rasulev U.K.  Int. J Mass Spectrometry, 1993, v128, 143-148

Drift-spectrometer for the control of amine traces in the atmosphere. Buryakov I.A., Krylov E.B., Makas A.L., Nazarov E.G., Pervukhin V.V., Rasulev K.  Zur. Anal. Khim (Russia) 1993, 48(1), 114-121

Separation of ions according to mobility in strong AC electric fields. Buryakov I.A., Krylov E.B., Makas A.L., Nazarov E.G., Pervukhin V.V., Rasulev K.  Soviet Tech. Phys. June 1991 Lett. 17(6)

 
Overview  
Intellectual Property  
Technical Papers  
Since its formation, the company has filed over 20 additional patents, covering various fields related to microDMS™ sensor chips.
View microDMx™ In Action